Eclipse Vortometric v2.00 Guide d'installation

Naviguer en ligne ou télécharger Guide d'installation pour Cuisiniers Eclipse Vortometric v2.00. Eclipse Vortometric v2.00 Installation guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Eclipse AirHeat Burners

Eclipse AirHeat BurnersAH Series version 2.00No. 135, 7/99L00061Installation GuideEclipse Combustion(Patent Pending)

Page 2 - WARRANTY

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9910Installation3INTRODUCTIONHANDLING ANDSTORAGEAPPROVALS OFCOMPONENTSLimit Controls and SafetyEq

Page 3 - About this manual

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9911All electrical wiring must comply with one of these standards:• NFPA Standard 70• ANSI-C11981

Page 4 - HOW TO GET HELP

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9912Air SupplyIf there are corrosive fumes or materials in the surroundingair, find an uncontamin

Page 5 - Table of contents

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9913In Duct MountingWhen laying out the duct, allow enough length downstream ofthe burner to avoi

Page 6

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9914Supply Piping• Locate the valve train close to the burner. The gas mustreach the burner duri

Page 7 - Introduction

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9915To verify the system was properly installed, perform thefollowing checks:1. Be sure there are

Page 8 - INTRODUCTION

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9916Adjustment, Start &Stop4In this chapter you will find instructions on how to start andsto

Page 9 - REPLACEMENT PARTS

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9917Step 3b: Ignite the burner(Option 2: Burner equippedwith spark ignited pilot)There are two s

Page 10 - Installation

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9918Step 4: Set high fire gas8. Adjust the outlet pressure from the main gas pressureregulator t

Page 11

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9919Maintenance &Troubleshooting5INTRODUCTIONThis chapter is divided into two sections:• Main

Page 12 - BURNER MOUNTING

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/992COPYRIGHTDISCLAIMER NOTICELIABILITY ANDWARRANTYCopyright 1999 by Eclipse Combustion, Inc. All

Page 13

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9920Yearly Checklist 1. Leak test the safety shut-off valves for tightness ofclosure.2. Test the

Page 14 - CONTINUED)

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9921PROBLEM POSSIBLE CAUSE SOLUTION• Air pressure switch has notmade contact.• High gas pressure

Page 15 - PREPARE FOR

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9922Burner does not achievecapacity.• Main gas control valve is notfunctioning.Check actuator and

Page 16 - Adjustment, Start &

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9923PROBLEM POSSIBLE CAUSE SOLUTION• Air pressure drop/velocity istoo low.Main flame is uneven al

Page 17 - Main Gas

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9924AppendixCONVERSIONFACTORSMetric to English.From To Multiply Bycubic meter (m3) cubic foot (ft

Page 18

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/9925AirHeatMain Gas ShutoffValve TrainGas CockSolenoid Valve(normally closed)Pressure RegulatorEc

Page 19 - Troubleshooting

Eclipse Combustion

Page 20 - • the flame sensors

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/993About this manualAUDIENCEThis manual has been written for people who are alreadyfamiliar with

Page 21 - TROUBLESHOOTING PROCEDURES

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/994There are several special symbols in this document. Youmust know their meaning and importance

Page 22

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/995Table of contents1About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . 3Au

Page 23

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/996Maintenance & Troubleshooting . . . . . . . . . . . . . . 19Maintenance . . . . . . . . .

Page 24 - Appendix

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/997Introduction1PRODUCTDESCRIPTIONEclipse AirHeat v2.00 Burners are line type burners ideal forge

Page 25 - SCHEMATICS

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/998Safety2This section is provided as a guide for the safe operation ofthe AirHeat burner system.

Page 26 - Eclipse Combustio

Eclipse AirHeat v2.00, Installation Guide No. 135, 7/999Only qualified personnel, with good mechanical aptitude andexperience on combustion equipment,

Commentaires sur ces manuels